Try 7 days of FREE access to billions of articles

Start Free Trial

San Antonio Light in San Antonio, Texas

We have 22,786,314 pages in Texas

View this page and access billions of articles with a 7-day free trial.

Start Free Trial

This is just the beginning! Our collection holds over 300 years of history, including rare newspapers, obituaries, marriage records, birth records, and so much more—most of which you won’t find anywhere else!

Start Free Trial

Cancel anytime, risk free

Not what you were looking for? Search our billions of articles

Advanced Search

Articles on This Page

This newspaper page contains 11 articles. Subscribers can read the full text of each article.

Newspaper

San Antonio Light

Location

San Antonio, Texas, United States of America

Date

Jul 19, 1913

Page

10

Fire safety code rules for boilers and furnaces in buildings

The notice outlines required fireproofing and clearances for brick and stone fire backs, boilers, hot air furnaces, registers, and flues. It specifies brick foundations, metal shields, ventilation gaps, and distances from timber, ceilings, and woodwork to prevent ignition.

Heating Safety Rules for Stoves and Smoke Pipes

The notice outlines clear safety standards for stoves and heating systems. It specifies proper support with iron legs, distances from woodwork, metal shields under ash pans, guard plates for burners, and metal coverings for adjacent wood. Gas connections must use metal pipes. Ash receptacles should be fireproof. Smoke pipes have minimum clearances, shielding, and installation rules, including ventilated thimbles when passing through partitions or roofs. Drying rooms require fireproof walls. Notices must be given to the Building Inspector for new or altered heating work and no hot air pipe may be concealed without inspection.

Asda

Building Code Provisions for Wood Beams and Structural Safety

The document sets detailed rules for wood beam placement, bracing, and connections in buildings, including required clearances from flues, anchoring to walls, end treatments, and trimmer or header connections. It also covers bridging, permits adjustments near chimneys, and ensures safe integration with girders, columns, and trusses.

Elevation and Elevator Enclosure Fire Safety Rules

The notice outlines requirements for fireproof elevator enclosures in brick or iron framed buildings, including trap doors double doors and skylights to extend above roofs, with strict materials and thickness, plus fire doors and self closing openings. It also covers dumb waiter shafts with fireproof walls and skylights, and guards at floor openings with weighted trap doors and gate standards.

Building Regulations on Bay Oriel and Show Windows

PART XI MISCELLANEOUS PROVISIONS Bay Oriel and Show Windows Section 76 allows street front or side windows to project at most one foot beyond the building line and require incombustible material. No projecting window may be within eighteen inches of a party line. Cornices Section 77 requires fireproof materials with iron anchors for future cornices and gutters, preventing overhangs beyond five feet.

Building Fire Safety Rules for Stairs and Fire Escapes

The section outlines required stairs for large office, factory, hotel, lodging, or school buildings with lot areas from 2500 to over 15000 square feet. It details minimum widths, uniform tread and riser sizes, landing placements, railings, and inspector-approved width increases for safety. It also covers exterior fire escapes, balconies, ladders, enclosures, skylights, doors, windows, and standpipes in tall buildings, plus penalties for obstructions and maintenance duties.

Gores. Spanner Fire Department

Fire safety code details standpipes sprinklers and shutters

The document outlines standpipe systems with Siamese connections on exterior walls, roof outlets, and required valves, plus automatic sprinkler requirements for mercantile and manufacturing buildings. It specifies fireproof doors and shutters, wire glass substitutes, and external shutters opened by firefighters, along with auxiliary fire appliances and district classifications.

National Board of Fire Underwriters Fire Department Buuilding

San Antonio Fire Code Divides Buildings Into Five Classes

The ordinance classifies all city structures into five classes based on fire resistance. First class includes fireproof and skeleton constructions, while second class uses brick or stone exterior walls. Third class covers mixed construction up to the first floor with more wood above, and fourth class consists of mean frame structures with wood or stucco finishes. Fifth class includes mean frame with metal siding. The City also divides the Fire Districts into A the Fire Proof District B Inner Fire District and C Outer Fire District.

City of San Antonio

Boundary Lines and Fire District Rules in San Antonio

A historic survey details boundary lines for First and Second Fire Limits and building restrictions in three districts. It outlines street-based perimeter lines around Dolorosa River Market areas, multiple cross streets, and river meanders, followed by fireproof construction rules for Districts A B and C with prohibitions on wooden sheds, required fire walls, roofing materials, and penalties for violations.

First Fire Limite Dolorosa Street San Pedro Creek Flores Street Dwyer Avenue San Antonio River Market Street East Commerce Street Bonham Street Blum and Crockett Streets Nacogdoches Street Fast Houston Street East Houston Street Avenue E St Houston Street Elk Building Avenue F Acrors Avenue FE Avenue D Travis Street Soledad Street Obraje Street Main Avenue North Flores Street

Height and area limits for frame buildings and brick wall rules

The code sets height limits for frame buildings including grain and coal elevators, with towers allowed up to ten feet above the limit and church spires up to 75 feet. It also restricts ground coverage by frame buildings to 7500 square feet for one story and 5000 for two stories, and requires fireproof wall construction near lot lines and fire stops between joists and partitions. The inspector may permit brick walls outside fire limits when combustible walls replace wood.

Public Buildings Fire Safety Rules For Assemblies

Building and fire officials direct egress in all public buildings including churches theaters and halls with aisles kept clear and only staff police or fire personnel may occupy aisles during performances to ensure public protection and safe evacuation.

Also Mentioned on This Page

Materia Paris Baildze Fourth Street Bowie Street Blum Street Live Oak Street Center Street Walnut Street Galveston Street Center of Galveston Str Sycamore Street Narp Street Matagorda Street Lafitte Street Water Street South Street South Alamo Street Beauregard Street Building District “Co Josephine Street Pine Street Nevada Street Durango Street McCullough Avenue Dewey Place Place of Beginning Spector
Search Courier

Search the San Antonio Light Today with a Free Trial

We want people to find what they are looking for at NewspaperArchive. We are confident that we have the newspapers that will increase the value of your family history or other historical research. With our 7-day free trial, you can view the documents you find for free.

Not Finding What You Were Looking for on This Page of The San Antonio Light?

People find the most success using advanced search. Try plugging in keywords, names, dates, and locations, and get matched with results from the entire collection of newspapers at NewspaperArchive!

Looking Courier

Browse Newspapers

You can also successfully find newspapers by these browse options. Explore our archives on your own!

By Location

By Location

Browse by location and discover newspapers from all across the world.

Browse by Location
By Date

By Date

Browse by date and find publications for a specific day or era.

Browse by Date
By Publication

By Publication

Browse old newspaper publications to find specific newspapers.

Browse by Publication