Special Fire Safety Rules for Fireplaces Boilers and Furnaces
The notice outlines required fireback thicknesses for brick and stone fireplaces, underfloor boiler protections, brick foundations under portable boilers, and metal shielding for ceilings and woodwork. It details hot air furnaces, registers, flues, steam and hot water pipes, ranges, and stoves with specified clearances, materials, and construction methods to prevent fire hazards in boiler rooms and heating systems.
Heating and wood beam building code guidelines summarized
The text specifies clear fire safety rules for stoves and chimneys, including iron supports, metal shields, guards, ventilation thimbles, and gas connections. It also covers ash receptacles, smoke pipe distances, roof permits, and required inspections. It then details wood beam construction, trimmer and header beams, wall anchors, girders, timber columns, trusses, and bolts with required washers.
Fire safety rules for walls roofs and awnings in city code
The document details construction and fireproofing requirements for exterior walls cornices bulkheads awnings stables and fences. It covers fireproofing for petroleum storage skylights ducts light and vent shafts and general prohibitions on combustible materials in walls and wainscoting with specific clearances and dimensions.
Fireproof Elevator Enclosures and Safety Guards Proposed
Special notice outlines standards for fireproof elevator enclosures and guards in brick or fireproof buildings. It details trap-doors with counterweights, tin casings, skylights, and iron or brick walls, plus door sills and wired glass limits. It requires inspections by the Building Inspector and specifies dumb waiter shafts and screens under elevator sheaves.
Building Projections and Cornice Rules Publicized
Part XI outlines misc provisions for street frontage bays oriels and show windows may project up to one foot from the building line and must be built of incombustible material. Projections must stay at least eighteen inches from a party line. Cornices and gutters must use fireproof material and be well anchored. No cornice may extend beyond five feet.
MENTIONED IN THIS ARTICLE
Fire Department
Seattle
National Board of Fire Underwriters
Fire safety height rules for stairs and fire escapes
The article sets mandatory fire protection standards for tall buildings including stair counts by lot area, width and tread rules, fire escape enclosures, exterior balconies, and required fireproof doors. It also details escalators, landing provisions, stair hall skylights, and bracketed iron supports, plus sections on standpipes and bulkhead access.
Standpipe and sprinkler requirements in fire safety code
Special notice outlines standpipe installation from cellar to roof with base-connected piping, hose specifications, Siamese connections, check valves, and roof drainage. It prescribes automatic sprinklers for mercantile and manufacturing buildings, elevates fire readiness, and mandates fireproof shutters and doors, exterior openings, and rolling shutter controls across high buildings.
MENTIONED IN THIS ARTICLE
Fire Department
Offire
National Board of Fire Underwriters
San Antonio Fire Building Classes and Districts Ordinance
The ordinance divides city buildings into five classes by fireproofing and materials: First class fireproof throughout, second class brick or stone walls, third class walls similar to second but with framed structure above first floor or wood on exterior beyond frames, fourth class mean frame with wood or brick/stone veneer, fifth class metal clad frames. Fire districts split the city into District A fireproof, District B inner fire, and District C outer fire, with definitions to be provided.
MENTIONED IN THIS ARTICLE
San Antonio
City of
Lee
Boundary Line of First Fire Limits in San Antonio
Boundary description establishes the Fire Limits district known as Fireproof District A. It traces a path from Dolorosa street at the San Pedro creek, along streets and river meanders, to Market and East Commerce streets, and returns via Bonham, Nacogdoches, Avenue lines, and the San Pedro creek. The boundary ends at the starting point near Dolorosa street.
MENTIONED IN THIS ARTICLE
First Fire Limits
Dolorosa Street
San Pedro Creek
Flores Street
Dwyer Avenue
San Antonio River
Market Street
South Alamo Street
East Commercce Street
East Commerce Street
Bonham Street
Blum and Crockett Streets
Nacogdoches Street
East Houston Street
Avenue E
Elk Building
Avenue F
Avenue D
Travis Street
Soledad Street
Obraje Street
Main Avenue
North Flores Street
West Houston Street
Camaron Street
West
Houston Street
West Commerce Street
Boundary Lines and Fire Districts in San Antonio
The article details Boundary Lines of Building Districts B and Co and the three fire districts A B and C. It outlines streets forming the limits from Fourth Street Bridge to various streets including Bowie, Live Oak, Center, Walnut, Galveston, and others. It also sets construction rules for each district from fireproof requirements to allowed building classes and penalties for violations.
Frame Building Height and Area Restrictions In Code
The section outlines height limits for frame buildings, limiting most to two stories and an attic of thirty feet, with towers and spires allowances. It also sets ground area caps for one and two story frame buildings and requires fireproofing measures near lot lines. Brick or stone alternatives allowed outside fire limits with inspector adjustments.
Public Buildings and Places of Assembly Regulation
Public buildings including churches theaters halls and other public assembly spaces must be arranged to aid quick egress in fire or accident and provide proper public protection. Aisles must be kept clear of obstructions and only employees police or firefighters may occupy aisles during performances or services.
Also Mentioned on This Page
Paris
Mmanner Desert
Fourth Street
Bowie Street
Blum Street
Live Oak Street
Center Street
Walnut Street
Galveston Street
Sycamore Street
Narp Street
Matagorda Street
Lafitte Street
Water Street
South Street
Beauregard Street
Washington Street
Arsenal Street
South Flores Street
Aransas Street
Durango Street
Santa Rosa Avenue
Buena Vista Street
Salado Street
Zavala Street
San Saba Street
Chavez Street
Salinas Street
Chavez and
Salinas Streets
Romana Street
Augusta Street
Lexington Avenue
Building District “Co
Josephine Street
Pine Street
Nevada Street
G. H
S. A
Queensborough Court
McCullough Avenue
Dewey Place
Place of Beginning