Special Notice on Fireplace and Boiler Fireproofing Standards
The article lists detailed requirements for fireplace firebacks walls and linings. It also prescribes clearances and protective coverings for boilers hot air furnaces pipes and stoves including brick foundations metal shields and ventilating spaces to prevent fires.
Special Notice on Heating Stoves and Wood Beam Rules
The document outlines heating appliance safety rules including stove support on iron legs or shields, front ash pan protection on wood floors, gas connections on metal pipes, and ash receptacles. It also covers smoke pipe clearances, stove and furnace guards, permit requirements for roof passages, and extensive wood beam, truss, and support specifications for fireproofing, anchoring, bracing, and timber workmanship.
Building Code Provisions on Fireproofing and Egress
The document details extensive fire safety rules for San Antonio including fireproofing of cornices awnings and bulkheads, stair exits and elevator hoistways, and storage of flammables. It mandates fireproof materials for roofs walls and ducts and sets dimensions for exits stalls runways and clearances in stables and storage areas.
Elevator and shaft safety provisions in brick or fireproof buildings
Building code notes require fireproof enclosures for water wells and elevator shafts. Steel or brick walls, trap-doors with tin-sides, skylights above shafts, and standard fire-doors with metal frames are mandated. Dumb waiters and shaft openings must be self closing and fireproof to protect occupants.
Provisions on Bay Oriel and Show Windows Construction
Text outlines requirements for street front and side projecting bays and show windows including projection limits, distance from party lines, and fireproof materials. It also covers cornice and gutter safety standards, requiring fireproof construction and iron anchorage.
Building Fire Safety Standards for Escapes and Stairs
Detailed historic zoning rules require multiple stair lines for large offices shops hotels and schools with minimum widths railings and uniform risers. Fire escapes balconies and ladders must meet strict construction inspection maintenance and obstructions rules with penalties for noncompliance.
Fire standpipes required in tall buildings per section rules
The text outlines standpipe requirements for buildings by height. In buildings 55 to 190 feet tall a 4 inch standpipe is needed, while buildings over 100 feet require 6 inch standpipes if not already present. Materials must be wrought iron or galvanized steel and withstand 300 psi with testing. Standpipes to be in fire proof stair enclosures or near stairs, with end stands for long or multi-street structures.
MENTIONED IN THIS ARTICLE
San Antonio
Jron
Fire Department
Fire safety code details for standpipes and sprinklers in tall buildings
The regulations require standpipes in stairwells connected to roof outlets with Siamese connections and valves, hoses meeting specific sizes, and ready access to extinguishers and spanners. Buildings over 100 feet must have auxiliary fire appliances and may require automatic sprinklers in mercantile and manufacturing districts, with pipe and connection standards to the fire department.
MENTIONED IN THIS ARTICLE
Fire Department
National Board of Fire Underwriters
Mercantile
Turing
San Antonio Fire Districts Classify Buildings by Construction
The ordinance divides the city into five building classes from fireproof to mean frame. It then establishes three fire districts A, B, and C with definitions to be provided for each district.
Boundary Line of First Fire Limits or Fireproof District A
Description of a historic boundary line starting at Dolorosa street south curb and following property lines and street curb references around Dolorosa, South Flores, Dwyer avenue, the San Antonio river, Market street, East Commerce street, Bonham, Blum and Crockett, Nacogdoches, East Houston, Avenue E, Avenue KE, Avenue D, Travis street, Obraje Street, Main avenue, West Houston, Camaron, West Commerce, and the San Pedro creek returning to the origin.
MENTIONED IN THIS ARTICLE
First Fire Limits
Dolorosa Street
San Pedro Creek
Flores’ Street
Dwyer Avenue
San Antonio River
Market Street
South Alamo Street
East Commerce Street
Bonham Street
Blum and Crockett Streets
Nacogdoches Street
East Houston Street
Avenue E
Elk Building
Avenue KE
Avenue D
Travis Street
Soledad Street
Obraje Street
Main Avenue
North Flores Street
West Houston Street
Camaron Street
West
Houston Street
West Commerce Street
Building District “Co
Josephine Street
Pine Street
Nevada Street
Walnut Street
G. H
S. A
Queensborough Court
McCullough Avenue
Dewey Place
Place of Beginning
Boundary Lines of Second Fire Limits and Building District B
Boundary descriptions outline the Second Fire Limits and Building District B and Co in San Antonio from the river on Fourth street through streets like Nacogdoches Bowle Live Oak Galveston and Beauregard to the Fourth street bridge. It details zones for Fireproof District A Inner Fire District C outer limits and construction rules with penalties for noncompliance.
Height Of Frame Construction Rules In The Code
The text sets height limits for frame buildings including two stories and a thirty foot attic with exceptions for grain and coal elevators and ice houses. It details tower limits, spire allowances, ground area coverage, clearance from lot lines, fireproofing requirements, fire stopping, and brick building allowances outside fire limits with inspector discretion.
Public Buildings Regulations on Aisles and Exits
The fire chief and building inspector direct the layout of aisles doors and seating in public buildings including churches theaters and stores to ensure safe evacuation. Aisles must be kept free of obstructions and only staff police or firefighters may occupy them during performances or services.
Also Mentioned on This Page
Pi Art A. Sr
City of
Antonio River
Fourth Street
Bowle Street
Live Oak Street
Center Street
Galveston Street
Sycamore Street
Narp Street
Matagorda Street
Lafitte Street
Water Street
South Street
Beauregard Street
Washington Street
Arsenal Street
South Flores Street
Aransas Street
Durango Street
Santa Rosa Avenue
Buena Vista Street
Salado Street
Zavala Street
San Saba Street
Chavez Street
Salinas Street
Chavez and
Salinas Streets
Flores Street
Romana Street
Augusta Street
Lexington Avenue
Stric
Inner Fire District
Spector