San Antonio Building Ordinance on Permits and Inspections
Special notice outlines city wide ordinance regulating construction alteration and removal in San Antonio. It establishes mayoral appointment of building inspectors sets permit requirements for new and altered structures and details filing plan specifications and approval process with timelines and record keeping.
MENTIONED IN THIS ARTICLE
City of
San An
San Antonio
Street and sidewalk safety and building operation rules
City ordinances govern business district construction with fences, planks, and protected walks. It restricts material storage, dictates guardrails, red lights, and overhead coverings while detailing definitions for building types and terms such as apartment houses and tenement houses.
Structural Code Detailing Building Load and Material Standards
Special notice outlining structural provisions for buildings including material quality cement and steel, calculation of stresses, floor and roof loads, column strength, footings, soil bearing, safe loads for masonry, wind design, and strength of materials with prescribed safety factors and testing requirements.
MENTIONED IN THIS ARTICLE
American Society For
Association of American Steel Manufacturers
Regulations on Walls and Fire Safety for New Buildings
The article outlines minimum brick wall thicknesses for various building types, party wall rules, bonding, linings, and parapet standards. It covers piers, chimneys, chases, hollow brick usage, and fire wall openings, with sprinkler requirements and limitations on wall projections between structures.
Mill and Buildings to Be Mill or Slow-Burning Construction
Section 44 requires theaters schools hotels and large apartment blocks to be built with mill or slow-burning or fireproof construction. Section 45 specifies structural dimensions materials and fireproof features for mill buildings including floors girders beams and fire doors. Section 46 defines slow-burning construction with metal lath plaster fireproofed ceilings and hollow space fire-stopping and double floors.
Fireproof Building Standards for Height and Materials
Eight story limits apply for stores and factories with fireproof construction. Exterior window frames must be metal. interior components may be metal or fireproof material. Fireproof partitions require iron studs. stairs use brick, stone, concrete or iron. Columns demand brick or concrete encasement. girders require brick or terra cotta casing and spacing. Floor arches and filling specify brick, hollow tile or concrete with proper rises and thickness. Incasing columns and girders enforces four inch fireproof covering with two inch minimums for flanges. Painting rules apply to riveted metal. reinforced concrete defined and described.
MENTIONED IN THIS ARTICLE
Inspector of Buildings
Committee On Fire and Fire Limits
Paris
Fireproof Reinforced Concrete Standards and Precautions
Building rules require minimum concrete cover for reinforcing bars and specify fire resisting thicknesses for reinforced concrete. Walls girders and floors must include surplus protecting concrete, joints must be designed to handle stresses, and field load tests may be demanded by the Building Inspector. Concrete mixing and placement must follow machine batch, proper curing, and formwork practices.
Building Demolition Rules and Inspector Powers
The ordinance requires demolition facts to be stated when planning new buildings. It mandates top down removal, wetting material to suppress dust, and ground lowering of disassembled parts. The Building Inspector may inspect and halt work and enter properties to enforce compliance, with police aiding in permit enforcement.
MENTIONED IN THIS ARTICLE
City of
San Antonio
Police Department
Definition notes for building wall types
The text defines Foundation Wall as the wall portion below the first tier above grade and interior walls below basement floor. Fire Wall covers parapet walls above the roof and partitions for fire protection. Retaining Wall is built to resist lateral earth pressure and internal loads.
Foundations rules for building bases and footings
The text outlines foundations rules for brick or stone buildings, prohibits building on filled earth, requires brick or stone, iron, steel, or concrete foundations, and details protection against rust, mortar for basement walls, limits on wood piles, and minimum footing and base course thicknesses for concrete or stone foundations with allowances by the Building Inspector for small structures.
Excavation Safety Rules for Adjacent Properties
Section details guard requirements for excavations to prevent danger to life. It requires underpinning or protection at owner expense when adjacent structures exist and mandates deep, frost-proof foundations for walls, piers, and columns to safely support loads.
Fireproof Construction Rules for Large Buildings
Section 47 outlines fireproof design requirements for buildings over 1000 seating, hotels, jails, hospitals and other tall or large structures. Walls must be brick stone or concrete with no wood beams. floors and roofs use steel or reinforced concrete, with noncombustible partitions and ceilings.
MENTIONED IN THIS ARTICLE
Ckecandnsessie
Kteel
Cspawsten
TOM Et
Vavgayes Cnscises
Oic
Ccccbvcasiscdys
Erns
Nets
Uss
Civbbelndkeedives
Portland
Rosendale
Sarah T
Oesetetese
Botno Vossecret
Caeeters Syoo
Corbi Maenee Sc
Shah
Son
Uemony
Cathynticotae
Prieet
Bae
Chimney and Hearth Construction Rules in Part IX
Building rules specify brick or combustible free chimneys, wall thicknesses, flue sizing, and fireproofing. It covers brickwork, lining, support from foundations, and safe clearance for chimneys on new and existing structures. It also details trimmer arches, plastering, hearth dimensions, and mantel materials for safe heating appliances.